{"id":67,"date":"2020-03-25T17:54:31","date_gmt":"2020-03-25T17:54:31","guid":{"rendered":"https:\/\/live-galileo.pantheonsite.io\/?post_type=products&#038;p=67"},"modified":"2020-06-25T18:32:58","modified_gmt":"2020-06-25T18:32:58","slug":"leak-detection-systems","status":"publish","type":"products","link":"https:\/\/www.galileotp.com\/pt\/products-services\/leak-detection-systems\/","title":{"rendered":"Leak Detection Systems"},"content":{"rendered":"<section class=\"block block-page-header no-margin color-white size-small align-middle justify-center overlay overlay-dark\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/Cell-1152x180.jpg') no-repeat center; background-size: cover;\">\n\t\t<div class=\"container\">\n\t\t<div class=\"row\">\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t<h1 class=\"heading-size-default\"><strong>Leak Detection Systems<\/strong><\/h1>\t\t\n\t\t\t<\/div>\n<\/section>\n\n\n<section class=\"block block-product-gallery no-margin has-bg no-margin block-padding bg-tertiary media-position-left media-fill-full-width\">\n\t<div class=\"container-fluid\">\n\t\t<div class=\"row\">\n\t\t\t\t\t\t\t<div class=\"col-lg-6 item-media item-carousel\">\n\t\t\t\t\t<div class=\"carousel carousel-with-thumbnails\"><div class=\"slide gallery-item-slide\" data-gallery-item-id=\"1\" data-caption=\"\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-1093x625.jpg') no-repeat center; background-size: contain;\"><\/div><div class=\"slide gallery-item-slide\" data-gallery-item-id=\"2\" data-caption=\"\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/Kairos-2-1093x625.jpg') no-repeat center; background-size: contain;\"><\/div><div class=\"slide gallery-item-slide\" data-gallery-item-id=\"3\" data-caption=\"\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-1093x625.jpg') no-repeat center; background-size: contain;\"><\/div><div class=\"slide gallery-item-slide\" data-gallery-item-id=\"4\" data-caption=\"\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-1093x625.jpg') no-repeat center; background-size: contain;\"><\/div><\/div><div class=\"carousel-thumbnails\"><div class=\"slide\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-570x308.jpg') no-repeat center; background-size: contain;\"><\/div><div class=\"slide\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/Kairos-2-570x308.jpg') no-repeat center; background-size: contain;\"><\/div><div class=\"slide\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-570x308.jpg') no-repeat center; background-size: contain;\"><\/div><div class=\"slide\" style=\"background: url('https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-570x308.jpg') no-repeat center; background-size: contain;\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\n\t\t\t<div class=\"col-lg-6 content-col card\">\n\t\t\t\t<div class=\"item-content\">\n\t\t\t\t\t<h3>Leak Detection Systems<\/h3>\t\t\t\t\t<div class=\"copy\"><p>We offer three types of leak detection systems for the refrigeration industry:<\/p>\n<ul>\n<li>Atmosphere &#8211; Tracer Gases<\/li>\n<li>Atmosphere &#8211; Refrigerants<\/li>\n<li>Vacuum Chamber<\/li>\n<\/ul>\n<\/div>\n\t\t\t\t\t<a class=\"btn  btn-outline btn-white\" href=\"https:\/\/www.galileotp.com\/pt\/contact\/\" target=\"_self\">Contact Us<\/a>\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t<div class=\"lightbox\">\n\t\t<div class=\"lightbox-backdrop\"><\/div>\n\t\t<div class=\"lightbox-inner container-fluid\">\n\t\t\t<div class=\"lightbox-close\">&times;<\/div>\n\t\t\t<div class=\"lightbox-prev\"><\/div>\n\t\t\t<div class=\"lightbox-image-wrap\">\n\t\t\t\t<div class=\"lightbox-image\"><\/div>\n\t\t\t<\/div>\n\t\t\t<div class=\"lightbox-next\"><\/div>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"block block-tabs\">\n\t<div class=\"container\">\n\t\t\t\t<div class=\"tab-labels\">\n\t\t\t\t\t\t\t<div class=\"tab-label shown load-shown bg-primary\" data-tab-id=\"0\">\n\t\t\t\t\t<h6>Atmosphere &#8211; Tracer Gases<\/h6>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"tab-label\" data-tab-id=\"1\">\n\t\t\t\t\t<h6>Atmosphere &#8211; Refrigerants<\/h6>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"tab-label\" data-tab-id=\"2\">\n\t\t\t\t\t<h6>Vacuum Chamber<\/h6>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<select class=\"mobile-tab-labels bg-primary\">\n\t\t\t\t\t\t\t\t\t\t\t\t<option selected value=\"0\">Atmosphere &#8211; Tracer Gases<\/option>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<option value=\"1\">Atmosphere &#8211; Refrigerants<\/option>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<option value=\"2\">Vacuum Chamber<\/option>\n\t\t\t\t\t\t\t\t\t<\/select>\n\t\t<div class=\"tab-items\">\n\t\t\t\t\t\t\t<div class=\"tab-item tab-id-0 shown load-shown\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"copy\"><h4><strong>ProbHe<img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-1087\" src=\"https:\/\/dev-galileo.pantheonsite.io\/wp-content\/uploads\/2020\/03\/leak-detection-right-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-right-300x300.jpg 300w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-right-150x150.jpg 150w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-right-768x768.jpg 768w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-right-345x345.jpg 345w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-right.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/strong><\/h4>\n<p><strong>ProbHe<\/strong>\u00a0has been designed and built to be used in any kind of assembly lines of cooling units (refrigerators, deep freezers, air conditioners etc\u2026)\u00a0 performing\u00a0 evacuation, pressurization with nitrogen for mechanical and gross leak test and pressurization by tracer gas (helium\/hydrogen mix) for\u00a0 fine leaks. Furthermore\u00a0<strong>ProbHe<\/strong>\u00a0can perform\u00a0 volume, flow and humidity measurements as well as\u00a0 flushing tests with nitrogen. The working phases for each cycle are fully programmable. In order to guarantee maximum quality and performance the system can be interfaced with the\u00a0<strong>Herec K<\/strong>\u00a0helium recovery system.<\/p>\n<p><strong>ProbHe<\/strong>\u00a0<strong>M<\/strong>\u00a0(<strong>M<\/strong>ultisniffer) features a manifold that connects up to 8 custom sniffing pliers (instead of using the leak detector sniffer probe). The manifold can be combined with the most common leak detectors in the market. Each plier has a specific led indicator that guarantees easier and faster readings. The main goal of the Multisniffer version is to reduce the human error in the leak detection, and it is particularly suited for high production rate lines.<\/p>\n<table style=\"border-collapse: collapse;width: 100%\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 25%;text-align: left\"><strong>Model<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\"><strong>Max working pressure<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\"><strong>Fluid inlet lines<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\"><strong>Number of fillers<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%\"><strong>ProbHe\/M<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\">45 bar<\/td>\n<td style=\"width: 25%;text-align: center\">2+2*<\/td>\n<td style=\"width: 25%;text-align: center\">2<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%\"><strong>ProbHe HP\/M<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\">140 bar<\/td>\n<td style=\"width: 25%;text-align: center\">4<\/td>\n<td style=\"width: 25%;text-align: center\">2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>*optional<\/em><\/p>\n<hr \/>\n<h4><strong>Kairos<\/strong><\/h4>\n<h4><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-1088\" src=\"https:\/\/dev-galileo.pantheonsite.io\/wp-content\/uploads\/2020\/03\/kairos-right-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-right-300x300.jpg 300w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-right-150x150.jpg 150w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-right-768x768.jpg 768w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-right-345x345.jpg 345w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-right.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/strong><\/h4>\n<p>Engineered and built to be used in any kind of small\/medium assembly lines (refrigerators, deep freezers, air conditioners, etc.), <strong>Kairos\u00a0<\/strong>performs evacuation, pressurization with nitrogen for mechanical stress tests and gross leak tests and pressurization by tracer gas (helium\/hydrogen mix) for\u00a0 fine leaks and final discharge. In order to guarantee the maximum quality and performance\u00a0 the system is interfaced with the\u00a0<strong>Herec K<\/strong>\u00a0helium recovery system.<\/p>\n<table style=\"border-collapse: collapse;width: 100%\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 25%;text-align: left\"><strong>Model<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\"><strong>Max working pressure<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\"><strong>Fluid inlet lines<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\"><strong>Number of fillers<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%\"><strong>Kairos<\/strong><\/td>\n<td style=\"width: 25%;text-align: center\">Up to 30 bar (40 bar*)<\/td>\n<td style=\"width: 25%;text-align: center\">2<\/td>\n<td style=\"width: 25%;text-align: center\">1+1*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><em>*optional<\/em><\/p>\n<p>&nbsp;<\/p>\n<hr style=\"clear: both\" \/>\n<h4><strong>Kairos Rec<\/strong><\/h4>\n<h4><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-1089\" src=\"https:\/\/dev-galileo.pantheonsite.io\/wp-content\/uploads\/2020\/03\/kairos-rec-right-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-rec-right-300x300.jpg 300w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-rec-right-150x150.jpg 150w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-rec-right-768x768.jpg 768w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-rec-right-345x345.jpg 345w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-rec-right.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/strong><\/h4>\n<p><strong>Kairos Rec<\/strong>\u00a0has been designed and built to be used in any kind of high production assembly line (refrigerators, deep freezers, air conditioners, etc.) performing the recovery of tracer gas used in previous stations up to 30 bar (<strong>ProbHe<\/strong>).<strong>\u00a0<\/strong><\/p>\n<p>It is possible to connect the leak detector and do the \u201csniffing\u201d\u00a0 of the piece under test already charged with a tracer gas (Helium).\u00a0<strong>Kairos Rec<\/strong>\u00a0can record the leak value read by the leak detector.<\/p>\n<p>In order to guarantee the maximum quality and performance the system can be interfaced with the\u00a0<strong>Herec K<\/strong>\u00a0helium recovery system and can be provided with or without vacuum pump.<\/p>\n<p>&nbsp;<\/p>\n<hr style=\"clear: both\" \/>\n<h4><strong>Kairos DT<\/strong><\/h4>\n<h4><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-1090\" src=\"https:\/\/dev-galileo.pantheonsite.io\/wp-content\/uploads\/2020\/03\/kairos-dt-right-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-dt-right-300x300.jpg 300w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-dt-right-150x150.jpg 150w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-dt-right-768x768.jpg 768w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-dt-right-345x345.jpg 345w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/kairos-dt-right.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/strong><\/h4>\n<p>Engineered and built to be used in any kind assembly lines of cooling unit (refrigerators, deep freezers, air conditioners, etc.) and hydronic unit.<\/p>\n<p><strong>Kairos DT\u00a0<\/strong>performs pressurization with nitrogen for mechanical stress tests and pressure decay test up to 30 bar.<\/p>\n<p>The pressure decay test can guarantee leak detection between 10<sup>-2<\/sup>\u00a0mbarl\/s and 10<sup>-4<\/sup>\u00a0mbarl depending on the unit and on the cycle configuration.<\/p>\n<p>It is particurarly indicated for testing of hydronic units and on cooling circuits as pre filtering station for detecting gross leaks or as substitute of water bubble test.<br \/>\n<br style=\"clear: both\" \/><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p><br style=\"clear: both\" \/>All the above listed Leak Detection Machines are completely integrated with\u00a0<strong>GEDA\u00a0<\/strong>system for data acquisition and statistics, remote programming as well as external supervision of the line.<\/p>\n<\/div>\t\t\t\t\t<a class=\"btn\" href=\"https:\/\/www.galileotp.com\/pt\/contact\/\" target=\"_self\">Contact Us<\/a>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"tab-item tab-id-1\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"copy\"><h4><strong>Multiref<\/strong><\/h4>\n<h4><strong><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1092 alignright\" src=\"https:\/\/dev-galileo.pantheonsite.io\/wp-content\/uploads\/2020\/03\/multiref-right-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-right-300x300.jpg 300w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-right-150x150.jpg 150w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-right-768x768.jpg 768w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-right-345x345.jpg 345w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/multiref-right.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/strong><\/h4>\n<p><strong>Multiref<\/strong> has been built for any type of cooling unit assembly lines (refrigerators, deep freezers, air conditioners, etc.) and it performs leak detection on refrigerant precharged units. The automatic leak detection is carried out by using the patented Galielo tp Multisniffer technology that guarantees objective readings of the leaks as well as traceability.<\/p>\n<p>The systems features a manifold that connects up to 8 custom sniffing pliers (instead of using the sniffer probe of the leak detector). The manifold can be interfaced with the most common leak detectors in the market. Each plier has a specific led indicator that guarantees easier and faster usage.<\/p>\n<p>The main goal of the machine is to reduce the human error in the leak detection process, and it is particularly suited for high production rate lines.<\/p>\n<p><strong>Multiref\u00a0<\/strong>is completely integrated with the\u00a0<strong>GEDA<\/strong>\u00a0system for data acquisition and statistics, remote programming as well as external supervision of the line.<\/p>\n<\/div>\t\t\t\t\t<a class=\"btn\" href=\"https:\/\/www.galileotp.com\/pt\/contact\/\" target=\"_self\">Contact Us<\/a>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"tab-item tab-id-2\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"copy\"><h4><strong>Helisystem<\/strong><\/h4>\n<h4><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-1094\" src=\"https:\/\/dev-galileo.pantheonsite.io\/wp-content\/uploads\/2020\/03\/helisystem-right-300x300.jpg\" alt=\"\" width=\"250\" height=\"250\" srcset=\"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-right-300x300.jpg 300w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-right-150x150.jpg 150w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-right-768x768.jpg 768w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-right-345x345.jpg 345w, https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/helisystem-right.jpg 800w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/strong><\/h4>\n<p><strong>Helisystem<\/strong>\u00a0is a measuring equipment of Galileo TP Process Equipment developed for highly sensitive leak detection with helium in vacuum chambers.<\/p>\n<p>The equipment performs an integral helium leak test at various pressures. It verifies the perfect tightness of the device under test by using the technique of the global test under vacuum chamber.\u00a0\u00a0<strong>Helisystem<\/strong>\u00a0is industrial equipment engineered according to customer needs, however, thanks to a dedicated industrialization and standardization process, it provides reliability, accuracy, efficiency and easy maintenance. In order to guarantee maximum quality and performance the system is interfaced with the\u00a0<strong>Herec K<\/strong>\u00a0helium recovery system.<\/p>\n<p>Thanks to our long time experience and advanced know-how we tailor the best solutions for the customer\u2019s needs.<\/p>\n<\/div>\t\t\t\t\t<a class=\"btn\" href=\"https:\/\/www.galileotp.com\/pt\/contact\/\" target=\"_self\">Contact Us<\/a>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t<\/div>\n<\/section>","protected":false},"parent":0,"menu_order":0,"template":"","product_industries":[],"class_list":["post-67","products","type-products","status-publish","hentry"],"acf":{"image":{"ID":1056,"id":1056,"title":"leak-detection-system","filename":"leak-detection-system.jpg","filesize":155026,"url":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","link":"https:\/\/www.galileotp.com\/pt\/products-services\/leak-detection-systems\/leak-detection-system\/","alt":"","author":"5","description":"","caption":"","name":"leak-detection-system","status":"inherit","uploaded_to":67,"date":"2020-06-18 16:34:27","modified":"2020-06-18 16:34:27","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.galileotp.com\/wp-includes\/images\/media\/default.png","width":2000,"height":1080,"sizes":{"thumbnail":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-300x162.jpg","medium-width":300,"medium-height":162,"medium_large":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-768x415.jpg","medium_large-width":768,"medium_large-height":415,"large":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-1024x553.jpg","large-width":1024,"large-height":553,"1536x1536":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-1536x829.jpg","1536x1536-width":1536,"1536x1536-height":829,"2048x2048":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","2048x2048-width":2000,"2048x2048-height":1080,"trp-custom-language-flag":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","trp-custom-language-flag-width":18,"trp-custom-language-flag-height":10,"call-to-action":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-2000x550.jpg","call-to-action-width":2000,"call-to-action-height":550,"header":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","header-width":2000,"header-height":1080,"header-small":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-2000x180.jpg","header-small-width":2000,"header-small-height":180,"header-medium":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-2000x400.jpg","header-medium-width":2000,"header-medium-height":400,"carousel":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-570x308.jpg","carousel-width":570,"carousel-height":308,"timeline":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-570x308.jpg","timeline-width":570,"timeline-height":308,"carousel-large":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-1093x625.jpg","carousel-large-width":1093,"carousel-large-height":625,"carousel-large-inset":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-639x345.jpg","carousel-large-inset-width":639,"carousel-large-inset-height":345,"industries":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-800x800.jpg","industries-width":800,"industries-height":800,"media-text-full":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-1040x705.jpg","media-text-full-width":1040,"media-text-full-height":705,"column":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-615x218.jpg","column-width":615,"column-height":218,"logo":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system-460x248.jpg","logo-width":460,"logo-height":248,"gform-image-choice-sm":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","gform-image-choice-sm-width":300,"gform-image-choice-sm-height":162,"gform-image-choice-md":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","gform-image-choice-md-width":400,"gform-image-choice-md-height":216,"gform-image-choice-lg":"https:\/\/www.galileotp.com\/wp-content\/uploads\/2020\/03\/leak-detection-system.jpg","gform-image-choice-lg-width":600,"gform-image-choice-lg-height":324}},"excerpt":""},"_links":{"self":[{"href":"https:\/\/www.galileotp.com\/pt\/wp-json\/wp\/v2\/products\/67","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.galileotp.com\/pt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.galileotp.com\/pt\/wp-json\/wp\/v2\/types\/products"}],"wp:attachment":[{"href":"https:\/\/www.galileotp.com\/pt\/wp-json\/wp\/v2\/media?parent=67"}],"wp:term":[{"taxonomy":"product_industries","embeddable":true,"href":"https:\/\/www.galileotp.com\/pt\/wp-json\/wp\/v2\/product_industries?post=67"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}