WIND
Home > Accessories for hc production line > WIND
WIND


The WIND systems have been designed to exhaust the flammable gases which might be present in the working or storage areas where these gases are used. WIND is available in two versions: WIND I (equipped with one single main exhaust fan) and WIND II (with one main exhaust fan and a back- up fan). WIND is composed of:
• Electrical control panel
• Main exhaust fan with 2 speed electrical motor
• Back-up exhaust fan with 2 speed electrical motor (only for WIND II version)
• Air flow sensor (e.g. differential pressure switch)
• Ventilation hoods to be installed in the various areas where these gases might be present (charging machines, storage systems, detection valves, recovery systems)
• Ventilation ductwork to the exhaust fans and exhaust ducted outside the working area into a safe zone. The electrical panel controls the exhaust fans operation according to the following incoming signals:
• Input to control sufficient ventilation air flow
• Input supplied by a gas detection system (CERBERUS) which indicates that a dangerous level of gas has been detected.
• Input supplied by microswitches to close the exhaust fans’ doors. The electrical control box is equipped with a contact which is open when it is in the stand-by mode or closed when it is working. Only in the working mode does this contact allow the ventilation system to supply the charging machines and the storage system through the CERBERUS or SUPER GUARD system.
• Electrical control panel
• Main exhaust fan with 2 speed electrical motor
• Back-up exhaust fan with 2 speed electrical motor (only for WIND II version)
• Air flow sensor (e.g. differential pressure switch)
• Ventilation hoods to be installed in the various areas where these gases might be present (charging machines, storage systems, detection valves, recovery systems)
• Ventilation ductwork to the exhaust fans and exhaust ducted outside the working area into a safe zone. The electrical panel controls the exhaust fans operation according to the following incoming signals:
• Input to control sufficient ventilation air flow
• Input supplied by a gas detection system (CERBERUS) which indicates that a dangerous level of gas has been detected.
• Input supplied by microswitches to close the exhaust fans’ doors. The electrical control box is equipped with a contact which is open when it is in the stand-by mode or closed when it is working. Only in the working mode does this contact allow the ventilation system to supply the charging machines and the storage system through the CERBERUS or SUPER GUARD system.